Last Modified: 11-29-2007 |
1.6 G |
|
Service Category: Vehicle Interior |
Section: Heating/Air Conditioning |
|
Model Year: 2008 |
Model: Sequoia |
Doc ID: RM000001JU400QX |
|
Title: HEATING / AIR CONDITIONING: SOLAR SENSOR: INSPECTION (2008 Sequoia) |
INSPECTION
1. INSPECT SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR)
(a) Remove the solar sensor with the connector still connected.
(b) Apply battery voltage between terminals 6 (CLTB) and 3 (CLTE) of the A/C solar sensor.
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
1 (TSL) - 3 (CLTE)
|
Sensor subject to electric light
|
0.8 to 4.3 V
|
|
1 (TSL) - 3 (CLTE)
|
Sensor covered with a cloth
|
Below 0.8 V
|
|
2 (TSR) - 3 (CLTE)
|
Sensor subject to electric light
|
0.8 to 4.3 V
|
|
2 (TSR) - 3 (CLTE)
|
Sensor covered with a cloth
|
Below 0.8 V
|
If the result is not as specified, replace the solar sensor.
HINT:
-
As the inspection light is moved away from the sensor, the voltage increases.
-
Use an incandescent lamp for inspection. Bring it within 30 cm (11.8 in.) of the solar sensor.
|